RLGB-80
RLGB-80 is a two stage Dual fuel burner, designed for a wide range of domestic and industrial applications. The values of CO and NOx during burner operation are lower than 30 and 120 mg/kWh; respectively, therefore, the burner’s NOx class of II is reported and approved.
-
Description
RLGB-80 Burner Equipments
RLGB-80 Burner Specifications
Value Unit Model Manufacturer Minimum Gas Rated Output 305 kW Main Motor 1.1 kW-Frame 80-B5 ABB Maximum Gas Rated Output 810 kW Pump Motor 550 W-GL 712-2-B34 GL LOHER Minimum Light Oil Rated Output 29 kg/h Pump AJ6CC Suntec Maximum Light Oil Rated Output 68 kg/h Control Box TMG740 Shokouh Minimum Gas Flow Rate 29.8 m3/h Main Gas Valve ZRDLE 415/5 Dungs Maximum Gas Flow Rate 79.4 m3/h Safety Gas Valve MVD 215/5 Dungs Gas Line Pressure 44 mbar Air Pressure Switch DG6U-3Z Krom schroder Input Gas Pipe Size 1 1/2 in Gas Pressure Switch DG50U-3Z Krom schroder Electric Power Supply Phase 3 — Electric Power Supply Frequency 50 Hz Electric Power Supply Voltage 220 V Fan Electrical Motor Power 1.1 kW Pump Electrical Motor Power 0.5 kW Fan Motor Speed 2850 rpm Pump Motor Speed 2850 rpm Stages 2 — Air Damper Automatic — Centrifugal Fan (Forward, CCW) 250 x 100 x 19 mm Weight 56 kg